screen grid ionization chamber spectrometer

图片1

Product Introduction

screen grid ionization chamber is an electron collection pulse ionization chamber commonly used to measure the energy of alpha particles or fission fragments. It includes a tablet and an additional pole (gate) to reduce the influence of heavy ions. The additional electrode is at an intermediate potential. On the one hand, the screen grid ionization chamber has the time characteristics of the electron collection block to improve the counting rate capacity, and at the same time eliminates the dependence of the output pulse amplitude of other similar ionization chambers on the initial ionization position, which can be used for particle energy measurement.

The use of screen ionization chamber to measure the nuclear reaction data of neutron-induced outgoing charged particles has some outstanding advantages, such as high particle detection efficiency (close to 100), the solid angle of detection is close to 4 & pi;, and the particle angle distribution, energy spectrum and double differential cross section data can be obtained at the same time. When the pressure of the working gas is changed, it can adapt to the measurement of different energy and different kinds of charged particles and has the particle resolution ability. These advantages make it an important means of measuring charged particles. The voltage of each pole is selected so that the electron collection satisfies the saturation condition and the gate non-trapping condition.

Screen grid ionization chamber spectrometer electronics system Shipingshan ionization chamber detector supporting electronics, its main function is to convert the ray signal measured by the screen grid ionization chamber into the user's visual map, through the map analysis to obtain the required information.

Product Features

  1. conversion gain: 1024,2048,4096 channel software adjustable;
  2. 3 coarse gain software adjustable, 0.5~1.5 times fine gain software adjustable;
  3. system zero point software adjustable;
  4. is stable and reliable for a long time, with zero drift less than 1 channel in 72 hours and gain instability less than 0.2% in 72 hours;
  5. zero temperature coefficient: less than 0.2 channels/°C; Gain temperature coefficient: less than 0.1%/°C;
  6. default USB communication, reserved serial port, can be extended to the network port, Bluetooth and other transmission methods;
  7. counting: 200Kcps;
  8. positive high voltage range of 0 ~ +5000V; with parameter storage, output voltage overload protection and other functions;
  9. negative high voltage range of 0 ~-5000V; with parameter storage, output voltage overload protection and other functions;
  10. built-in lithium battery power supply, the use of not less than 12 hours;
  11. hardware free warranty for one year, software lifetime free upgrade;
  12. open all software interface, convenient for users secondary development;
  13. can be customized according to the needs of software, hardware functions;
  14. optional spectral analysis software: GammaSense.